Gas Chromatography, Persee G5
Key Features
◆ Stability
The double adjustment design of voltage-stabilizing valve and stable-flow valve or needle valve is used in the pneumatic system. The use of Digital scale knob achieves the characteristics of high precision, good repeatability, convenient and intuitive flow adjustment
◆ Accurate
The stable gas flow and temperature control combined with high sensitivity detector bring you more accurate qualitative and quantitative analysis results
◆ Intelligent
The computer-controlled system, large-screen LCD display, multiple temperature protection and data network transmission make it possible to realize the laboratory digital management
◆ Powerful
Different configuration of optional injectors and detectors can meet a variety of analysis needs. Anti-control software can realize more excellent expansion of configuration, and it is convenient, time-saving and labor-saving
◆ Injector
Packed column injector and capillary split / splitless injector are optional. Available for the installation of a variety of columns (stainless steel columns, glass columns, capillary columns), can realize the perfect combination of 5 kinds of injections and can load up to three kinds of injectors simultaneously
◆ Detector
Six kinds of high-performance detectors are optional, namely FID, TCD, FPD, NPD, ECD and PID. Three detectors can be installed simultaneously. It is very easy to install additional detectors after purchasing the equipment
Temperature control
Temperature range 7 ℃ above room temperature (R.T.) ~ 400 ℃ (1 ℃ increment)
Temperature control items Oven, front / rear detector, front / rear injector, auxiliary, 6 parts in total
Temperature programming 7-stages temperature programming (Anti-control software supports 10 – stages temperature programming)
Temperature programmed rate setting 0.1 ℃~ 40 ℃/min (0.1 ℃ increment, measured at 200 ℃)
Hydrogen Flame Ionization Detector(FID)
Detection Limit ≤7×10-12 g/s (n-hexadecane)
Noise ≤ 2×10-13 A
Drift ≤ 4×10-13 A/30 min
Linear range 107
Thermal Conductivity Detector (TCD)
Sensitivity ≥ 6000 mV·mL/mg (Benzene)
Noise ≤ 0.04 mV
Drift ≤ 0.2 mV/ 30min
Linear range 104
Flame Photometric Detector (FPD)
Detection Limit ≤8×10-13 g/s (P) (Parathion-methyl)
Linear range 104
Detection Limit ≤8×10-11 g/s (S) (Parathion-methyl)
Linear range 103
Noise ≤ 4×10-13 A
Drift ≤ 1×10-12 A/30 min
Nitrogen and phosphorus detector (NPD)
Detection Limit ≤5×10-13 g/s (N) (Azobenzen)
Linear range 103
Detection Limit ≤5×10-14 g/s (P)(Malathion)
Linear range 103
Noise ≤ 2×10-13 A
Drift ≤ 1×10-12 A/30 min
Available accessories include:
-Headspace sampler
-Hydrogen generator
-Oil free air generator
-Nitrogen generator