HI2002-01 edge® Dedicated pH/ORP Meter

HI2002-01 edge® Dedicated pH/ORP Meter

Model No – HI2002-01

Condition – New/Refurbished

Manufacturer – Edge

Shipping – 3 to 5 Business days (CAN/US)/ 5 to 10 Business days (International Shipping)

Lease Rental – Available

Add to cart
Categories:

HI2002-01 edge® Dedicated pH/ORP Meter

edge® Dedicated pH/ORP Meter
pH Specifications
pH Range -2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode)
pH Resolution 0.001 pH, 0.01 pH
pH Accuracy (@25ºC/77ºF) ±0.01 pH, ±0.002 pH
pH Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*
mV Range ±1000.0 mV; ±2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
Relative mV Calibration Single point calibration
Temperature Specifications
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±0.9 °F
°C/°F Yes
Additional Specifications
pH Electrode Diagnostics Glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time
GLP Yes
Logging up to 1000*** records organized in: Manual log-on-demand (Max. 200 logs), Manual log-on-stability (Max. 200 logs), Interval logging *** (Max. 600 samples; 100 lots)
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)
Ordering Information edge® HI2002 digital pH meter includes benchtop docking station with electrode holder, wall mount cradle, USB cable, HI11310 glass body refillable pH electrode with temperature sensor, 2 sachets each of pH 4, 7, 10, cleaning solution, 5 VDC power adapter and instruction manual.
Warranty 2 years (probe 6 months)
Notes
* temperature limits will be reduced to actual probe/sensor limits
*** For standard mode only (logging)
† pH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer