Scientific Equipment Source | 4-555 Wentworth Street East Oshawa, ON, L1H 3V8 | Tel: 905-231-0930

Waters HPLC parts list

 

High Pressure Filter Assembly Part Number: 700002742 Located behind the front panel, the high pressure filter assembly (pulse dampner) reduces the pressure pulsations in the HPLC pump. The original part number was WAS207072 and it has changed to p/n 700002742. High Pressure Filter Assembly

High Pressure Filter Assembly

1515 HPLC Pump; 1525 EF HPLC Pump; 1525 HPLC Pump; 1525 Micro HPLC Pump; 515 HPLC Pump

Part Number: 700002742

 

Barbed Fitting, Wash Valve Part Number: 405003016 This barbed fitting is used in the wash valve of the 1525, 1525 micro and 1525 EF HPLC pumps. It is also used in the 1525 micro pump head. Barbed Fitting, Wash Valve

Part Number: 405003016

 

Mounting Bracket, Wash Pump Part Number: 400001417 This spare part is a genuine Waters Quality Part Mounting Bracket, Wash Pump

Part Number: 400001417

 

1525 EF Pump Head Assembly Part Number: 700002281 The 1525EF Pump Head Assembly draws in and delivers eluent. It also defines pump head capacity. 1525 EF Pump Head Assembly

Part Number: 700002281

 

1525 EF Plunger Seal (1/pkg) Part Number: 700002282 The 1525EF Plunger Seal helps maintain the pressure in the pump head. A damaged plunger seal will result in leaking from the pump head and needs to be replaced immediately. 1525 EF Plunger Seal (1/pkg)

1525 EF Plunger Seal (1/pkg)

Part Number: 700002282

 

Drawoff Valve Assembly Part Number: WAS207085 The Drawoff Valve Assembly is the mechanism that primes the pump heads with mobile phase in the 515 HPLC pump, the 1515 HPLC pump, and the 1525 HPLC pump. Drawoff Valve Assembly

 Drawoff Valve Assembly

Part Number: WAS207085

 

Indicator Rod Update Kit (225µL) Part Number: WAT069583 The Indicator Rod Update Kit contains the following parts: two Teflon® washers, two compression springs, and two molded indicator rods. Indicator Rod Update Kit (225µL)

Indicator Rod Update Kit (225µL)

Part Number: WAT069583

 

Ball and Seat Outlet Check Valve (225µL) Part Number: WAT025216 This prefabricated valve unit saves installation time and reduces the handling of small parts, as compared with the valve replacement process using the corresponding valve rebuild kit [Part Number WAT026014]. The valve is convenient and easy to install in… Ball and Seat Outlet Check Valve (225µL)

Ball and Seat Outlet Check Valve (225µL)

Part Number: WAT025216

 

Lower Drip Tray Part Number: 700001091 The Lower Drip Tray catches fluid leaks and routes them to the waste container. Lower Drip Tray

Lower Drip Tray

Part Number: 700001091

 

Injector Valve Drip Tray Part Number: 700001092 The Injector Valve Drip Tray catches leaking fluids from the injector. Injector Valve Drip Tray

Injector Valve Drip Tray

Part Number: 700001092

 

Outlet Check Vlv Housing, Ball and Seat Part Number: WAT025207 This Outlet Check Valve Housing is used for the 225µL pump heads. Outlet Check Vlv Housing, Ball and Seat. 1525 EF HPLC Pump; 510 HPLC Pump; 515 HPLC Pump; 600 MultiSolvent Delivery System; 610 PowerLine™ Isocratic Pump; LC Module 1

Outlet Check Vlv Housing, Ball and Seat

Part Number: WAT025207

 

LH Outlet Tubing Assembly Part Number: 430001254 This part number was originally WAS207083 and it was changed to part number 430001254 in Dec. 2007. LH Outlet Tubing Assembly. 1515 HPLC Pump; 1525 EF HPLC Pump; 1525 HPLC Pump; 1525 Micro HPLC Pump; 515 HPLC Pump

LH Outlet Tubing Assembly

Part Number: 430001254

 

Pump Head Support Bushing, (225µL) Part Number: WAT060305 This spare part is a genuine Waters Quality Part Pump Head Support Bushing, (225µL). 1525 EF HPLC Pump; 510 HPLC Pump; 515 HPLC Pump; 600 MultiSolvent Delivery System; 610 PowerLine™ Isocratic Pump; LC Module 1

Pump Head Support Bushing, (225µL)

Part Number: WAT060305

 

LH Inlet Tubing Assembly Part Number: 430001253 This part number was originally WAS207081 and changed to part number 430001253 in December 2007. LH Inlet Tubing Assembly. 1515 HPLC Pump; 1525 EF HPLC Pump; 1525 HPLC Pump; 1525 Micro HPLC Pump; 515 HPLC Pump

LH Inlet Tubing Assembly

Part Number: 430001253

 

RH Inlet Tubing Assembly Part Number: 430001256 This part number was originally WAS207082 and was changed to part number 430001256 in December 2007. RH Inlet Tubing Assembly. 1515 HPLC Pump; 1525 EF HPLC Pump; 1525 HPLC Pump; 1525 Micro HPLC Pump; 515 HPLC Pump

RH Inlet Tubing Assembly

Part Number: 430001256

 

Inlet Check Valve, Ball and Seat (225µL) Part Number: WAT060307 This prefabricated valve unit saves installation time and reduces the handling of small parts, as compared with the valve replacement process using the corresponding valve rebuild kit [Part Number WAT088223). The valve is convenient and easy to install in… Inlet Check Valve, Ball and Seat (225µL). 1525 EF HPLC Pump; 510 HPLC Pump; 515 HPLC Pump; 600 MultiSolvent Delivery System; 610 PowerLine™ Isocratic Pump; LC Module 1; PrepLC 4000

Inlet Check Valve, Ball and Seat (225µL)

Part Number: WAT060307

 

RH Outlet Tubing Assembly Part Number: 430001255 This part number was originally WAS207084 and changed to part number 430001255 in December 2007. RH Outlet Tubing Assembly. 1515 HPLC Pump; 1525 EF HPLC Pump; 1525 HPLC Pump; 1525 Micro HPLC Pump; 515 HPLC Pump

RH Outlet Tubing Assembly

Part Number: 430001255

 

Inlet Check Valve Housing (225µL) Part Number: WAT060308 This Inlet Check Valve Housing is used with check valves that fit into pump heads stamped with a #3. Inlet Check Valve Housing (225µL). 1525 EF HPLC Pump; 510 HPLC Pump; 515 HPLC Pump; 600 MultiSolvent Delivery System; PrepLC 4000

Inlet Check Valve Housing (225µL)

Part Number: WAT060308

 

Plunger, Extended Flow (225µL) Part Number: WAT060304 The sapphire plunger is 3/16in. in diameter and works with the pump head stamped with a #3 on the front. Plunger, Extended Flow (225µL). 1525 EF HPLC Pump; 510 HPLC Pump; 515 HPLC Pump; 600 MultiSolvent Delivery System; 610 PowerLine™ Isocratic Pump; LC Module 1

Plunger, Extended Flow (225µL)

Part Number: WAT060304

 

Active Seal Wash Kit, 1525EF Part Number: 205000252 This spare part is a genuine Waters Quality Part Active Seal Wash Kit, 1525EF

Part Number: 205000252

 

Reference Valve Part Number: WAT026592 The reference valve is a simple diverter, allowing your system to be bypassed during priming or solvent changes. Users can operate pumps at any flow rate, without damage to columns. The valve can be added to any Waters model 510, 515, or 600 pump. Reference Valve. 1525 EF HPLC Pump; 1525 HPLC Pump; 510 HPLC Pump; 600 MultiSolvent Delivery System; 610 PowerLine™ Isocratic Pump

Reference Valve

Part Number: WAT026592

 

Seal Wash Tubing, PharMed, 36in. Part Number: 700002505 This spare part is a genuine Waters Quality Part Seal Wash Tubing, PharMed, 36in.

Part Number: 700002505

 

1525EF PERFORMANCE MAINTENANCE KIT Part Number: 201000160 The Waters® Performance Maintenance Kit for the 1525EF pump contains all the Waters Quality Parts® necessary to keep your 1525EF pump operating at peak performance. The kit also contains a detailed maintenance protocol, including calibration and diagnosti… 1525EF PERFORMANCE MAINTENANCE KIT

Part Number: 201000160

 

Fuse, 3.15A (250V, 5 x 20mm) Part Number: 700001800 The 3.15A fuse is used in ACQUITY UPLC TUV detectors through serial number K05UPT699N. This part number replaces part numbers WAS163-16 and WAT055634 which were used for many detectors and pumps. Fuse, 3.15A (250V, 5 x 20mm)

Part Number: 700001800

 

Barbed Fitting, Head Support, 1525 EF Part Number: 405002915 This spare part is a genuine Waters Quality Part Barbed Fitting, Head Support, 1525 EF

Part Number: 405002915

 

Extended Flow Upgrade Kit (225µL)

Extended Flow Upgrade Kit (225µL)

Product Number: WAT094003

 

Plunger w/Indicator Rod Part Number: WAT031788 The Plunger with Indicator Rod (for 50µL head) is used in the 616/626 pumps and contains the following parts: one plunger assembly, one indicator rod, one plunger spring, and one compression spring. Plunger w/Indicator Rod

Part Number: WAT031788

 

Seal Enhancement Kit

The Seal Enhancement Kit consists of the following parts: two plunger and indicator rod kits, two seal retainers, one new seal package, and two pump head assemblies without check valves

Product Number: WAT047635

 

Outlet Check Valve Rebuild Kit (225µL). 510 HPLC Pump; 515 HPLC Pump; 600 MultiSolvent Delivery System; 610 PowerLine™ Isocratic Pump; LC Module 1

Outlet Check Valve Rebuild Kit (225µL)

Part Number: WAT026014

 

Ball and Seat Check Valve Kit Part Number: WAT088223 The Ball and Seat Check Valve Kit contains the following parts: two seal housings, two inlet check valve retainer balls, two inlet check valve guides, two inlet check valve ball & seats, two inlet check valve seal guides, two Teflon® O-rings, two check va… Ball and Seat Check Valve Kit. 510 HPLC Pump; 600 MultiSolvent Delivery System; LC Module 1

 

Part Number: WAT088223