HP 5890 Series II GC

The Hewlett Packard (Agilent) HP-5890 has been the standard of gas chromatography for laboratories throughout the world. From the initial introduction of HP 5890A to the HP 5890-II with electronic pressure control, this GC has stood the test of time. The 5890 is still widely used in many laboratories. A refurbished 5890 provides todays laboratory with a reliable GC at a fraction of the price of a new system. Many system configurations are available and we have a system that fits your budget requirements. 


Scientific Equipment Source will customize a GC specifically for your laboratory to include everything you want. Remember all our GCs come refurbished with new parts and carry our complete ONE-YEAR PARTS AND LABOUR WARRANY and our PHONE TECHNICAL SUPPORT. Each GC comes ready to go. We can lease or rent a system to you to help fit your budget requirements. 


Here are some of the most common set ups. 

  • 5890 Series II single injector (split/split less or Packed) single FID detector 7500.00 USD 
  • 5890 Series II single injector (split/split less or Packed) single TCD detector 10,500.00 USD 
  • 5890 Series II dual injectors (split/split less or Packed) dual FID detectors 9,500.00 USD 
  • 5890 Series II dual injectors (split/split less or Packed) dual TCD detectors 12,500.00 USD 
  • 5890 Series II dual injectors (split/split less or Packed) dual FID/TCD detectors 11,500.00 USD
  • All of the above systems come with INET communications (HPIB and data system is available. 

Here are some of the many options available.

  • Inlet Systems
    • 5890 PI (Packed Inlet)
    • 5890 SSI (Split/Splitless Inlet)
    • 5890 Temperature Prog. On-Column Inlet
    • 5890 Split/Splitless Inlet w/EPC (Series-II w/#039 only)
    • 5890 Temp Prog. On-Column Inlet w/EPC (Series-II w/#039 only)
  • Detector Systems
    • 5890 FID (Flame Ionization Detector)
    • 5890 TCD (Thermal Conductivity Detector)
    • 5890 ECD (Electron Capture Detector)
    • 5890 FPD (Flame Photometric Detector)
    • 5890 NPD (Nitrogen Phosphorous Detector)
  • Communication Interfaces
    • 5890 INET Communications
    • 5890 RS-232 Communications
    • 5890 HP-IB Communications
  • Flow & Pressure Control
    • 5890 EPC Module
    • 5890 Set of Three Mini-internal Regulators
  • Cryogenic Oven Control
    • 5890 CO2 Cryo Control
    • 5890 N2 Cryo Control
  • Heated Valve Oven
    • Installation, Automation 1-valve on 5890
    • Installation, Automation 2-valves on 5890
    • Installation, Automation 3-valves on 5890
    • Installation / Automation 4-valves on 5890
    • 6-port Valve for 5890
    • 10-port Valve for 5890
  • Custom Plumbed
    • Liquid Sampling Valve, 0.2uL, 1000psi, 75C for 5890
    • Liquid Sampling Valve, 0.5uL, 1000psi, 75C for 5890
    • Liquid Sampling Valve, 1.0uL, 1000psi, 75C for 5890
    • Liquid Sampling Valve, 0.5uL, 5000psi, ambient for 5890

Need parts for your 5890 II? Check out our 5890 II parts support. 
Here are some of the available add on items for the HP 5890 II 

HPIB communications ADD 865.00 USD
Gas sampling valve and valve oven 3000.00 USD
Data Integrator ADD 700.00 USD
Chemstation Software with computer 4,900.00 USD
Printer ADD 215.00 USD

Auto sampler 7673A including tower, sample tray, and controller set up on inet communications, including cables and cords. 5500.00CN 3900.00 USD

Mounting bracket and HPIB (IEEE) communications available at extra cost.

Type A Tray only 2050.00Can 1500.00 USD
Type A Tower only 2300.00Can 1800.00 USD
Type A Controller only 2100.00Can 1600.00 USD
Type A Bracket only 525.00Can 400.00 USD
Trade in any type A controllers, towers or trays and receive 150.00 USD off for each.


Auto sampler 7673B including tower, sample tray, and controller set up on inet communications, including cables and cords. 7,280.00CN 6400.00 USD

Mounting bracket and HPIB (IEEE) communications available at extra cost.

Type B Tray only 2750.00Can 2100.00 USD
Type B Tower only 3500.00Can 2700.00 USD
Type B Controller only 2750.00Can 2100.00 USD
Type B Bracket only 715.00Can 550.00 USD
Trade in any type B controllers, towers or trays and receive 250.00 USD off for each.

Specifications:

  • Heated Devices
    • Five heated zones standard: Two detectors, Two inlets, one auxiliary
    • Methods stored: Two
  • Split/Splitless Capillary
    • Range to 400C in 1C increments
    • Back-pressure design permits independent adjustment of split flow rate without affecting column flow
    • Septum purge built in at 3 ml/min
    • Accepts columns up to 1.2-mm od
    • Multimode design includes split and splitless injection
    • Splitless purge time variable in 0.01-min elements
  • Flame Ionization Detector
    • Range to 450C
    • Grounded jet and current limited design for operator safety
    • Push-button flame ignition
    • Sensitive:
      • 18 mCoul/gm carbon: nitrogen carrier, 0.018-in. id jet
      • 15 mCoul/gm carbon: helium carrier, 0.018-in. id jet
      • 22mCoul/gm carbon: nitrogen carrier, 0.018-in. id capillary jet
      • 18 mCoul/gm carbon: helium carrier, 0.018-in. id capillary jet
    • Minimum detectable: 5 pg carbon/sec, nitrogen carrier at S/N=2
    • Linear dynamic range: +/- 10% over a 10 7 range with 0.018-in. id jet
    • Conditions: column flow 50 ml/min, 45 ml/min H2, 650 ml/min air, propane sample
  • Thermal Conductivity Detector
    • Range to 400 C
    • Single-filament (single column) design has fluidic switching of reference and analytical carrier flows
    • Minimum detectable :400 pg/ml carrier -- equivalent to 1 pmm neon in 1 ml air
    • Linear dynamic range:+/- 5% over 105 range
    • Digital gain setting time-programmable through the keyboard Conditions: detector
    • 100 C, 45 ml/min switching and 30 ml/min analytical flow of helium, propane sample
  • Flame Photometric Detector
    • Range to 300 C
    • 100-530 u id capillary columns fit through the transfer line to the base of the flame
    • Two combustion modes: air/hydrogen or oxygen/hydrogen
    • Detector signal display to view when flame is lit
    • Push-button flame ignition
    • Sulfur mode: Sensitivity to 20 pg S/second, Range 103, Selectivity 105 g S/g C
    • Phosphorus mode: Sensitivity to 0.9 pg P/second, Range 104, Selectivity 106 g P/g C
  • Column Oven
    • Operating range: 4 C above ambient to 450 C
    • Setpoint entry: 1 C for temperatures, 0.1 C for program rates
    • Programming: Rates 0.1 to 70 C per min, 650 min maximum run time, Three ramps with initial/final holds

If you are a bargain hunter please give us a call, we always have instruments in stock, which have not been refurbished and can be sold as is in working condition.

Scientific Equipment Source provides service and training on site in most of central Ontario this includes neighboring cities Ajax, Whitby, Pickering, Oshawa, Toronto, Mississauga. We can also provide training and courses on site on chromatograph (GC), HPLC in the Durham region; this includes Pickering, Ajax, Whitby, Oshawa. For other customers we can be also flexible on arrangements. For the rest of customer any equipment for repair has to be sent back by a courier.